There are 75 papers on pulse rate in aging research: 19 trials and 43 observational studies in people, 2 in animals, 4 reviews.
75 papers study it61 more mention it17 findings
13 new papers in 30 daysSee all 136 papers on pulse rate
“pulse rate -0.00194 (95% CI -0.00317--0.000705)”
- Human trial19
- Humans43
- Animals2
- In silico6
Interventions
8Eloralintide
downin humans1
1 study
Eloralintide
downin humans1
Eloralintide decreases pulse rate in humans.
Review
Circulo massage + stretching
downin humans1
1 study
Circulo massage + stretching
downin humans1
Circulo massage + stretching decreases pulse rate in humans (hypertension) (87.25 to 74.80 (14.26%), p=0.000).
Human trialhypertensionn = 20
Jasmine and champaca aromatherapy combined with acupressure
downin humans1
1 study
Jasmine and champaca aromatherapy combined with acupressure
downin humans1
Jasmine and champaca aromatherapy combined with acupressure decreases pulse rate in humans (non-communicable diseases and poor sleep quality) (p < 0.001).
Human trialnon-communicable diseases and poor sleep qualityessential oil aromatherapy combined with acupressure6 weeks
More on Jasmine and champaca aromatherapy combined with acupressure
Standing on an elevated platform
upin humans1
1 study
Standing on an elevated platform
upin humans1
Standing on an elevated platform increases pulse rate in humans (Higher or moderate concern about falls; elevated surface compared with floor).
Human trialHigher or moderate concern about falls; elevated surface compared with floor0.6 m elevation
Isometric handgrip exercise
downin humans1
1 study
Isometric handgrip exercise
downin humans1
Isometric handgrip exercise decreases pulse rate in humans (one hour post exercise).
Human trialone hour post exercise30% of maximal voluntary contractionn = 87
Orforglipron
upin humans1
1 study
Orforglipron
upin humans1
Orforglipron increases pulse rate in humans (type 2 diabetes inadequately controlled with metformin; versus oral semaglutide) (+3.7 and +4.7 bpm with orforglipron 12 mg and 36 mg versus +1.0 and +1.5 bpm with semaglutide 7 mg and 14 mg).
Human trialtype 2 diabetes inadequately controlled with metformin; versus oral semaglutideoral12 mg or 36 mg once daily52 weeksn = 1,698
Lithium
downin humans1
1 study
Lithium
downin humans1
Lithium is linked with lower pulse rate in humans (prescribed lithium).
Humansprescribed lithiumn = 591
In vitro maturation
downin mice1
1 study
In vitro maturation
downin mice1
In vitro maturation decreases pulse rate in mice (optimized in vitro matured group compared with in vivo matured group) (P = 0.0119).
Animalsoptimized in vitro matured group compared with in vivo matured group
Effects
1Cardiovascular disease
mediatesin humans1
1 study
Cardiovascular disease
mediatesin humans1
Pulse rate is linked with cardiovascular disease in humans (from 10 year to 20 year follow-up) (from 6.3% to 29.3%).
Humansfrom 10 year to 20 year follow-up20 years
Upstream
2Sex
no changein humans1
1 study
Sex
no changein humans1
Sex was not clearly linked with pulse rate in humans (men compared with women) (84.0±18.9 vs 81.2±16.0 beats/min; p=0.54).
Humansmen compared with womenn = 71
Anxiety disorders
upin humans1
1 study
Anxiety disorders
upin humans1
Anxiety disorders are linked with higher pulse rate in humans (lifetime history of anxiety disorders vs healthy controls).
Humanslifetime history of anxiety disorders vs healthy controls
Associations
6Moderate-to-vigorous physical activity
downin humans1
1 study
Moderate-to-vigorous physical activity
downin humans1
Moderate-to-vigorous physical activity is associated with pulse rate in humans (UK university students; multivariable adjustment and false-discovery-rate correction) (β = −0.146; q = 0.447; not significant).
HumansUK university students; multivariable adjustment and false-discovery-rate correctionn = 111
In-hospital mortality
upin humans1OR 1.05
1 study
In-hospital mortality
upin humans1OR 1.05
Pulse rate predicts in-hospital mortality in humans (Geriatric trauma) (Adjusted OR 1.05, 95% CI 1.002–1.093).
HumansGeriatric traumaUntil hospital discharge or deathn = 360
Cognitive function
downin humans1
1 study
Cognitive function
downin humans1
Pulse rate is associated with cognitive function in humans.
Humansn = 41
Mortality
upin humans1OR 1.039
1 study
Mortality
upin humans1OR 1.039
Pulse rate predicts mortality in humans (hip fracture) (OR 1.039, 95% CI 1.002-1.078).
Humanship fracturen = 319
Telomere length
downin humans1
1 study
Telomere length
downin humans1
Pulse rate is associated with telomere length in humans (adjusted for immune cell type distributions) (-0.00194 kilobase pairs per unit; 95% CI -0.00317 to -0.000705).
Humansadjusted for immune cell type distributionsleukocyten = 7,252
Death or ICU admission
upin humans1
1 study
Death or ICU admission
upin humans1
Pulse rate is associated with death or ICU admission in humans (pulse rate greater than 90 beats/min; after ED discharge) (AOR 1.66; 95% CI 1.02 to 2.71).
Humanspulse rate greater than 90 beats/min; after ED dischargewithin 7 days of dischargen = 600
Funding
1 grant since 2017Japan Society for the Promotion of Science¥4.2M