30-s chair-stand test

There are 32 papers on 30-s chair-stand test in aging research: 12 trials and 17 observational studies in people, 1 review. The newest story, Oct 5, 2026: “30-second chair stand test is linked to peak oxygen uptake”.

Biomarker

32 papers study it52 more mention it6 findings

2 new papers in 30 daysSee all 84 papers on 30-s chair-stand test

“the change in lower-limb training volume between the OEC and SDE periods was significantly and positively correlated with the change in CS-30 performance [r = 0.802, P < 0.05”
Continued benefits of online supervised bodyweight training for lower-limb function in older adults: A single-arm pilot studyAging Medicine and Healthcare2026doi:10.4103/amah.amh-2025-07-093
  • Human trial12
  • Humans17

Interventions

1

Whey protein

no changein humans1

1 study
  1. Whey protein showed no clear effect on 30-s chair-stand test in humans (combined with low-intensity resistance training, versus isoenergetic placebo) (median change standard test: 0 (IQR 0, 5) protein v. 2 (IQR 0, 6) placebo).

    “no additional effect of PrS was seen for the primary endpoint (30-s chair stand test, repetitions”

    Human trialcombined with low-intensity resistance training, versus isoenergetic placebo27.5 g whey protein/dduring hospitalisation and 12 weeks after dischargen = 141

    Protein supplementation combined with low-intensity resistance training in geriatric medical patients during and after hospitalisation: a randomised, double-blind, multicentre trial

    The British journal of nutrition

More on Whey protein

Upstream

1

Brachial-ankle pulse wave velocity

no changein humans1

1 study
  1. Brachial-ankle pulse wave velocity was not clearly linked with 30-s chair-stand test in humans.

    “baPWV was not associated with the 30s-CST and 2MST.”

    Humansmalesn = 291

    Arterial stiffness expressed as brachial-ankle pulse wave velocity and gait assessment independent of lower extremity strength: a cross-sectional study in the older men population

    Journal of geriatric cardiology : JGC

More on Brachial-ankle pulse wave velocity

Associations

3

Peak VO2

upin humans1

1 study
  1. 30-s chair-stand test predicts peak VO2 in external validation cohort (Facility B) (r = 0.654, p < 0.001).

    “In the external validation cohort, predicted peak VO2 showed a moderate correlation with observed peak VO2 (r = 0.654, p < 0.001)”

    Humansin external validation cohort (Facility B)

    30-second chair stand test is linked to peak oxygen uptake

    International journal of cardiology. Heart & vasculature

  2. 30-s chair-stand test is associated with peak VO2 in humans after multivariable adjustment.

    “CS-30 performance was independently associated with peak VO2 after multivariable adjustment.”

    Humansafter multivariable adjustmentn = 3,577

    30-second chair stand test is linked to peak oxygen uptake

    International journal of cardiology. Heart & vasculature

More on Peak VO2

Resistance training

upin humans1

1 study
  1. Resistance training is associated with 30-s chair-stand test in humans (r = 0.802, P < 0.05).

    “the change in lower-limb training volume between the OEC and SDE periods was significantly and positively correlated with the change in CS-30 performance [r = 0.802, P < 0.05”

    Human trialn = 8

    Continued benefits of online supervised bodyweight training for lower-limb function in older adults: A single-arm pilot study

    Aging Medicine and Healthcare

More on Resistance training

Low bone stiffness

upin humans1

1 study
  1. 30-s chair-stand test predicts low bone stiffness in humans (AUC 0.744, P < 0.001).

    “ROC analysis identified a CS-30 cutoff of 25 repetitions for detecting low bone stiffness, with an area under the curve of 0.744 (P < 0.001).”

    Humansfemalesn = 382

    Muscle Performance as a Predictor of Bone Health: Among Community-Dwelling Postmenopausal Japanese Women from Setagaya-Aoba Study

    Calcified tissue international

Latest

Dec 2025: 1Jan 2026: 1Feb 2026: 2Mar 2026: 1Apr 2026: 3May 2026: 1Jun 2026: 0Jul 2026: 1Aug 2026: 0Sep 2026: 3Oct 2026: 2Nov 2026: 116 papers in 12 months
International Journal of Cardiology Heart & Vasculature

30-second chair stand test is linked to peak oxygen uptake

In an external validation cohort, predicted peak VO₂ correlated with observed values at r = 0.654, with a root mean square error of 4.73 mL/kg/min.In an external validation cohort, predicted peak VO₂ correlated with observed values at r = 0.654, with a root mean square error of 4.73 mL/kg/min.

Cohort study of 3,577 peopleBiomarkers

See all 84 papers on 30-s chair-stand test