There are 415 papers on 30-second chair stand test in aging research: 171 trials and 195 observational studies in people, 27 reviews.
415 papers study it37 more mention it24 findings
14 new papers in 30 daysSee all 452 papers on 30-second chair stand test
“Data from 10 patients showed good agreement between the manually collected and sensor-collected 30CST data (M = 0.5, SD = 1.58, 95% CI = 1.13).”
- Human trial171
- Humans195
Interventions
3Exercise
upin humans2
2 studies
Exercise
upin humans2
Exercise improves 30-second chair stand test in older adults with good sleep quality (p = 0.011).
“A significant group × time interaction was observed for the 30 s chair stand test (p = 0.011), with the GS group showing greater improvements in lower-extremity muscular endurance.”
Human trialin older adults with good sleep quality12 weeksn = 8
Applied Sciences
Exercise improves 30-second chair stand test in humans (ΔRTE = .150).
“Significant improvements with moderate effects for time*group were found in lower-limb strength [30s-chair-stand: χ 2(1.84) = 5.127, p < .001, ΔRTE = .150]”
Human trialmulticomponent fitness training and introductory recreational sportstwo weekly 90-minute sessions24 weeksn = 161
Frontiers in sports and active living
Tele-pulmonary rehabilitation
upin humans1
1 study
Tele-pulmonary rehabilitation
upin humans1
Tele-pulmonary rehabilitation improves 30-second chair stand test in humans (elderly COPD patients).
“the intervention group showed significantly better performance in both 30 s CST and 30 s ACT at 3, 12, and 24 months compared to the control group”
Human trialelderly COPD patientsBCW theory-based tele-pulmonary rehabilitation24-month follow-upn = 60
Chinese Journal of Geriatrics
High-intensity interval training
upin humans1
1 study
High-intensity interval training
upin humans1
High-intensity interval training improves 30-second chair stand test in sleeve and bypass surgery patients (+ 26.97% for sleeve and + 27.47% for bypass).
“while HIIT in both the sleeve and bypass groups significantly improved Sit-to-Stand performance (+ 26.97% for sleeve and + 27.47% for bypass, p < .05)”
Human trialin sleeve and bypass surgery patients8 weeksfemalesn = 40
BMC musculoskeletal disorders
Upstream
1VO2peak
no changein humans1
1 study
VO2peak
no changein humans1
VO2peak was not clearly linked with 30-second chair stand test in humans (stage I to III breast cancer survivors) (r=0.30, P=0.1).
“correlations between VO 2 peak and the 30CST performance or fatigue did not reach statistical significance (r=0.30 and r=-0.28, P=0.1)”
Humansstage I to III breast cancer survivorsfemalesn = 32
Physiology
Associations
18Locomotive syndrome progression
upin humans1OR 1.24
1 study
Locomotive syndrome progression
upin humans1OR 1.24
30-second chair stand test is associated with locomotive syndrome progression in humans after adjusting for age (OR 1.24, p = 0.04).
“Logistic regression revealed a significant association between the CS-30 change and LS maintenance/improvement (OR 1.24, p = 0.04) after adjusting for age.”
Humansafter adjusting for age2 yearsn = 58
Nihon Ronen Igakkai zasshi. Japanese journal of geriatrics
30-second chair stand test predicts locomotive syndrome progression in humans (AUC = 0.705).
“CS-30 showed a moderate predictive ability (AUC = 0.705), with a cutoff of+1 repetitions”
Humans2 yearsn = 58
Nihon Ronen Igakkai zasshi. Japanese journal of geriatrics
Locomotive syndrome
downin humans1OR 0.81
1 study
Locomotive syndrome
downin humans1OR 0.81
30-second chair stand test is linked with a lower risk of locomotive syndrome in humans (progression; adjusted for age) (OR 0.81, 95% CI 0.66-0.99).
“In age-adjusted logistic regression models, increases in CS-30 (odds ratio [OR] 0.81, 95% confidence interval [CI] 0.66-0.99) and SRT (OR 0.91, 95% CI 0.83-0.99) were significantly associated with reduced risk of LS progression.”
Humansprogression; adjusted for age2 yearsn = 58
Journal of rural medicine : JRM
Mortality
downin humans1
1 study
Mortality
downin humans1
30-second chair stand test is linked with a lower risk of mortality in humans (highest vs lowest performance quintile) (AHR 0.55, 95% CI 0.46-0.65).
“30-second chair stand (AHR, 0.55 [95% CI, 0.46-0.65])”
Humanshighest vs lowest performance quintilemedian follow-up of 7.0 yearsn = 13,423
Physical Fitness and All-Cause Mortality in Older Adults
JAMA network open
Upper-limb isokinetic strength
mixedin humans1
1 study
Upper-limb isokinetic strength
mixedin humans1
30-second chair stand test is associated with upper-limb isokinetic strength in humans (apparently healthy) (r = -0.13-0.30).
“whereas the 30CS showed inconsistent correlations (r = -0.13-0.30).”
Humansapparently healthyn = 327
Functional fitness tests and their association with upper-limb isokinetic strength in older adults
Aging clinical and experimental research
Jump kinetics
upin humans1
1 study
Jump kinetics
upin humans1
30-second chair stand test is associated with jump kinetics in humans.
“The kinetics of the 30-s chair test is correlated with the kinetics of both SJ and CMJ.”
Humansn = 12
Unlocking mobility: A kinetic perspective on the 30-second chair stand test in older adults
Journal of bodywork and movement therapies
SarQoL score
upin humans1
1 study
SarQoL score
upin humans1
30-second chair stand test is associated with SarQoL score in peritoneal dialysis patients (r=0.46, p=0.02).
“the SarQoL score was correlated with diastolic blood pressure (r=0.50, p=0.003), serum albumin (r=0.47, p=0.006), diuresis (r=0.46, p=0.007), number of stands at the chair test (r=0.46, p=0.02)”
Humansin peritoneal dialysis patientsn = 32
Nefrología
Cognitive function
upin humans1
1 study
Cognitive function
upin humans1
30-second chair stand test is associated with cognitive function in humans (β = 0.33, p < 0.001).
“For men, only the 30-chair stand test power (β = 0.33, p < 0.001) presented favourable association with cognitive function.”
Humansmalesn = 312
Healthcare (Basel, Switzerland)
Balance Evaluation Systems Test
upin humans1
1 study
Balance Evaluation Systems Test
upin humans1
30-second chair stand test predicts Balance Evaluation Systems Test in humans (Chronic Obstructive Pulmonary Disease) (1.22-point increase).
“Each additional 30s CST repetition predicted a 1.22-point increase in BESTest scores”
HumansChronic Obstructive Pulmonary Diseaseeach additional repetitionn = 244
Respiratory medicine
Color Trails Test 1
downin humans1
1 study
Color Trails Test 1
downin humans1
30-second chair stand test is associated with Color Trails Test 1 in humans (at baseline) (r = -0.296).
“better performance in the 30-second chair stand test was associated with faster completion time in CTT-1 at baseline (r = -0.296).”
Human trialat baseline
Science progress
Gait speed
upin humans1
1 study
Gait speed
upin humans1
30-second chair stand test is associated with gait speed in humans (β = 0.513, p < 0.001).
“Standardised coefficients of the linear models were: 30 s-AC (β=0.593), 30 s-CS (β=0.513), 5-CS (β=-0.431), and HGS (β=0.475) (all p < 0.001).”
Humansfemalesn = 142
Evaluating handgrip strength and functional tests as indicators of gait speed in older females
Frontiers in sports and active living
Sensor-integrated chair
upin humans1
1 study
Sensor-integrated chair
upin humans1
Sensor-integrated chair is associated with 30-second chair stand test in humans (M = 0.5, SD = 1.58, 95% CI = 1.13).
“Data from 10 patients showed good agreement between the manually collected and sensor-collected 30CST data (M = 0.5, SD = 1.58, 95% CI = 1.13).”
Human trialn = 10
Sensor-Integrated Chairs for Lower Body Strength and Endurance Assessment
Sensors (Basel, Switzerland)