Normothermic machine perfusion

Normothermic machine perfusion has been studied in 22 papers since 2019: 3 observational studies in people, 8 in animals, 9 reviews; 18 in the past year. The newest paper, Nov 23, 2026: “Kidney transplantation – current evidence and future developments in machine perfusion”.

Exposure

22 papers study it19 findingsUpdated

3 new papers in 30 daysSee all 22 papers on normothermic machine perfusion

At a glance

The findings reach people, from one lab or study. 7 independent labs in 6 countries.

“Applying the perfusion protocol in nontransplantable human donor livers enabled 7-d NMP in 4 livers, while control livers deteriorated after 66 [48-84] h NMP.”
Establishing a Platform for 1-Wk Normothermic Machine Perfusion of Donor LiversTransplantation2026doi:10.1097/tp.0000000000005915

None of its findings points the other way.

Cells, mice and humans: a single group. Worms or flies: nothing yet.
  • 7 independent labs in 6 countries
  • Funders: China Scholarship Council and others
  • 1 of 19 findings with company ties
  • Humans3
  • Animals8

What did studies of normothermic machine perfusion find?

16

Studies of normothermic machine perfusion measured 16 outcomes, among them inflammation, ex situ liver preservation and early apoptosis.

Inflammation

upin human cells1upin mice1

2 studies
  1. Normothermic machine perfusion increases inflammation in mice (compared with oxygenated hypothermic machine perfusion).

    Animalscompared with oxygenated hypothermic machine perfusionkidney

  2. Normothermic machine perfusion induces inflammation in human cells (paired kidneys compared with cold static storage; RNA sequencing).

    Cellspaired kidneys compared with cold static storage; RNA sequencingkidney1 hourn = 4

More on Inflammation

Ex situ liver preservation

upin humans1upin pigs1

1 study
  1. Normothermic machine perfusion improves ex situ liver preservation in humans (Nontransplantable human donor livers studied ex situ) (7-day preservation in 4 livers; control deterioration after 66 [48–84] hours).

    Human trialNontransplantable human donor livers studied ex situLong-term ex situ liver preservation protocol using OrganOx Metraliver7 daysn = 22

  2. Normothermic machine perfusion improves ex situ liver preservation in pigs (Ex situ porcine livers) (7-day perfusion with stable function and preserved morphology).

    AnimalsEx situ porcine liversLong-term ex situ liver preservation protocol using OrganOx Metraliver7 daysn = 18

early apoptosis

upin mice1

1 study
  1. Normothermic machine perfusion increases early apoptosis in mice.

    Animalskidney-resident immune cell

Immune cell mobilization out of the graft

upin mice1

1 study
  1. Normothermic machine perfusion increases immune cell mobilization out of the graft in mice (compared with oxygenated hypothermic machine perfusion).

    Animalscompared with oxygenated hypothermic machine perfusionkidney

Tubular injury

upin mice1

1 study
  1. Normothermic machine perfusion increases tubular injury in mice (compared with oxygenated hypothermic machine perfusion).

    Animalscompared with oxygenated hypothermic machine perfusionkidney

Kidney injury

upin pigs1

1 study
  1. Normothermic machine perfusion increases kidney injury in pigs.

    Animalskidneyafter 3 h

Cold ischemia time

upin humans1

1 study
  1. Normothermic machine perfusion is linked with higher cold ischemia time in humans (median 37.6 vs 22.1 hours).

    Humanskidney

Graft survival

no changein humans1

1 study
  1. Normothermic machine perfusion was not clearly linked with graft survival in humans.

    Humanskidney

Delayed graft function

downin humans1

1 study
  1. Normothermic machine perfusion is linked with lower delayed graft function in humans (26.3% vs 60.2%).

    Humanskidney

More on Delayed graft function

Rescue of declined kidneys for transplant

upin humans1

1 study
  1. Normothermic machine perfusion is linked with higher rescue of declined kidneys for transplant in humans (kidneys that exhausted standard allocation) (94 of 104 (90%) rescued).

    Humanskidneys that exhausted standard allocationkidney2 hoursn = 104

All 16

What is normothermic machine perfusion linked with?

1

Studies link normothermic machine perfusion with graft function.

Graft function

upin humans1

1 study
  1. Normothermic machine perfusion is associated with graft function in humans (fatty liver graft from a nonagenarian donor).

    Humansfatty liver graft from a nonagenarian donorOrganOx Metraliver7 months of follow-upmales

Latest

Dec 2025: 2Jan 2026: 5Feb 2026: 2Mar 2026: 3Apr 2026: 0May 2026: 0Jun 2026: 0Jul 2026: 1Aug 2026: 0Sep 2026: 0Oct 2026: 3Nov 2026: 218 papers in 12 months

See all 22 papers on normothermic machine perfusion