Transcatheter aortic valve implantation

Transcatheter aortic valve implantation has been studied in 107 papers since 2016: 1 trial and 92 observational studies in people, 13 reviews; 31 in the past year. The newest paper, Nov 12, 2026: “Prognostic Value of Tissue Doppler Late Diastolic Velocity (TDI-a’) in Patients with Severe Aortic Stenosis Undergoing Transcatheter Aortic Valve Implantation”.

Intervention

107 papers study it54 findingsUpdated

5 new papers in 30 daysSee all 106 papers on transcatheter aortic valve implantation

At a glance

Transcatheter aortic valve implantation is linked with lower mortality and better function and quality of life in human studies, changes reported by independent labs. Other studies report no clear mortality or functional link, or higher mortality. Comparisons with surgery link it with more vascular complications; papers report Medtronic funding, company-affiliated authors and declared company ties.

54 findings in 27 papers from 2016 to 2026, 4 of them since May 2026

Independent labs found the same change in people. 26 independent labs in 16 countries.

“Memory performance improved significantly (Word List Learning + 2.13 (± 3.22) words; P < 0.001; Word List Recall + 1 word; P < 0.001)”
App-based assessment of neurocognitive changes in patients undergoing transcatheter aortic valve implantation - a prospective cohort studyJournal of geriatric cardiology : JGC2026doi:10.26599/1671-5411.2026.07.003

6 of its findings point the other way.

Humans: replicated by independent labs. Cells, worms or flies and mice: nothing yet.
  • 26 independent labs in 16 countries
  • 6 findings against
  • Funders: Forskningsrådet om Hälsa, Arbetsliv och Välfärd and others
  • 11 of 53 findings with company ties
  • Human trial1
  • Humans91

Studies in people

1 study gave transcatheter aortic valve implantation to people and measured what changed.

What changedDesignPeopleSource

up: Improves lower extremity function45.0 to 52.0, p < 0.001

up: Improves upper extremity function11.4 to 6.8, p = 0.003

Randomized trial30 daysPatient cohortsCatheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions, Jan 13, 2026

What did studies of transcatheter aortic valve implantation find?

25

Studies of transcatheter aortic valve implantation measured 25 outcomes; the most studied are mortality (6 studies), quality of life (4) and cognitive function (3).

Mortality

downin humans4no changein humans2HR 0.24–0.73

6 studies
  1. Transcatheter aortic valve implantation is linked with lower mortality in humans after TAVI explant (HR: 0.73 [CI, 0.58-0.92]).

    Humansafter TAVI explant

  2. Transcatheter aortic valve implantation is linked with lower mortality in humans (symptomatic severe aortic stenosis) (HR 0.24, 95% CI 0.15-0.37).

    Humanssymptomatic severe aortic stenosis2-year

  3. Transcatheter aortic valve implantation is linked with lower mortality in humans (symptomatic severe aortic stenosis) (18% vs. 44%).

    Humanssymptomatic severe aortic stenosis1 yearn = 192

  4. Transcatheter aortic valve implantation is linked with lower mortality in humans (10.3% vs 2.9% vs 1.2%, P < 0.001).

    Humans30 days

  5. Transcatheter aortic valve implantation was not clearly linked with mortality in humans (Surgical high-risk severe aortic stenosis; compared with surgical aortic valve replacement) (5.8% versus 11.4%; P=0.622).

    HumansSurgical high-risk severe aortic stenosis; compared with surgical aortic valve replacement1 year

  6. Transcatheter aortic valve implantation was not clearly linked with mortality in humans.

    HumansPropensity-matched patients with symptomatic severe aortic stenosis; compared with surgical aortic valve replacementearly and midterm

Quality of life

upin humans4

4 studies
  1. Transcatheter aortic valve implantation improves quality of life in humans after TAVI.

    Human trialafter TAVIn = 100

  2. Transcatheter aortic valve implantation is linked with better quality of life in humans after TAVI (+25 (IQR 10-38), p=0.001).

    Humansafter TAVI30 daysn = 19

  3. Transcatheter aortic valve implantation is linked with better quality of life in humans.

    Humans12 monthsn = 101

  4. Transcatheter aortic valve implantation is linked with better quality of life in humans (severe aortic stenosis) (Slight improvement; not statistically significant).

    Humanssevere aortic stenosisn = 65

Cognitive function

no changein humans3

3 studies
  1. Transcatheter aortic valve implantation showed no clear effect on cognitive function in humans (undergoing TAVI).

    Human trialundergoing TAVIn = 112

  2. Transcatheter aortic valve implantation showed no clear effect on cognitive function in humans (symptomatic aortic stenosis referred for TAVI) (21.9 vs 21.79, p = 0.73).

    Human trialsymptomatic aortic stenosis referred for TAVI1 yearn = 84

  3. Transcatheter aortic valve implantation was not clearly linked with cognitive function in humans (nonagenarian patients undergoing TAVI) (24.1 ± 3.9 vs. 24.3 ± 4.6, p = 0.923).

    Humansnonagenarian patients undergoing TAVIn = 38

Physical function

upin humans2

2 studies
  1. Transcatheter aortic valve implantation is linked with better physical function in humans after TAVI (+39 (30-50), p<0.001).

    Humansafter TAVI30 daysn = 19

  2. Transcatheter aortic valve implantation is linked with better physical function in humans (severe aortic stenosis with preserved EF after TAVI).

    Humanssevere aortic stenosis with preserved EF after TAVI

Functional status

no changein humans1upin humans1

2 studies
  1. Transcatheter aortic valve implantation was not clearly linked with functional status in humans (severe aortic stenosis) (TAVI -0.53 vs. SAVR + 0.47).

    Humanssevere aortic stenosis6 monthsn = 155

  2. Transcatheter aortic valve implantation is linked with better functional status in humans (survivors with severe aortic stenosis at high surgical risk).

    Humanssurvivors with severe aortic stenosis at high surgical riskself-expanding Medtronic CoreValve prosthesis4 years

Executive function

no changein humans1

1 study
  1. Transcatheter aortic valve implantation showed no clear effect on executive function in humans (undergoing TAVI).

    Human trialundergoing TAVIn = 112

Memory

upin humans1

1 study
  1. Transcatheter aortic valve implantation improves memory in humans (undergoing TAVI) (+ 2.13 (± 3.22) words, P < 0.001).

    Human trialundergoing TAVIn = 112

Frailty

downin humans1

1 study
  1. Transcatheter aortic valve implantation is linked with lower frailty in humans (severe aortic stenosis) (80% to 62%, p = 0.001).

    Humanssevere aortic stenosis3 months postimplantationn = 184

Left ventricular mass

downin humans1

1 study
  1. Transcatheter aortic valve implantation is linked with lower left ventricular mass in NF-HG, LF-HG, and LF-LG patients.

    Humansin NF-HG, LF-HG, and LF-LG patients6 months

More on Left ventricular mass

Grip strength

no changein humans1

1 study
  1. Transcatheter aortic valve implantation was not clearly linked with grip strength in humans (nonagenarian patients undergoing TAVI) (17.4 ± 7.1 vs. 16.1 ± 7.4 kgf, p = 0.102).

    Humansnonagenarian patients undergoing TAVIn = 38

Upper extremity function

upin humans1

1 study
  1. Transcatheter aortic valve implantation improves upper extremity function in humans (11.4 to 6.8, p = 0.003).

    Human trial30 days

Lower extremity function

upin humans1

1 study
  1. Transcatheter aortic valve implantation improves lower extremity function in humans (45.0 to 52.0, p < 0.001).

    Human trial30 days

Six-minute walk distance

upin humans1

1 study
  1. Transcatheter aortic valve implantation improves six-minute walk distance in humans after TAVI.

    Human trialafter TAVIn = 100

Step count

no changein humans1

1 study
  1. Transcatheter aortic valve implantation showed no clear effect on step count in humans after TAVI.

    Human trialafter TAVIone weekn = 75

More on Step count

All 25

What is transcatheter aortic valve implantation linked with?

15

Studies link transcatheter aortic valve implantation with 15 measures, most often mortality (3 studies).

Mortality

upin humans1mixedin humans1downin humans1

3 studies
  1. Transcatheter aortic valve implantation is associated with mortality in humans (severe symptomatic aortic stenosis) (44% vs 26%, P < 0.01).

    Humanssevere symptomatic aortic stenosismean follow-up period of 3 yearsn = 36

  2. Transcatheter aortic valve implantation is associated with mortality in humans (high- and intermediate-risk women) (4%).

    Humanshigh- and intermediate-risk womennew-generation devices30 daysfemalesn = 331

  3. Transcatheter aortic valve implantation is associated with mortality in humans (Surgical high-risk severe aortic stenosis; compared with drug therapy) (5.8% versus 54.9% with drug therapy).

    HumansSurgical high-risk severe aortic stenosis; compared with drug therapy1 year

Pulse pressure

upin humans1

1 study
  1. Transcatheter aortic valve implantation is associated with pulse pressure in humans (Severe aortic stenosis; compared with preoperative baseline) (Baseline, POD1, POD2: 63.0, 74.0, 66.0 mmHg; P < 0.001).

    HumansSevere aortic stenosis; compared with preoperative baselinePostoperative days 1 and 234.2% malesn = 427

More on Pulse pressure

Blood pressure

mixedin humans1

1 study
  1. Transcatheter aortic valve implantation is associated with blood pressure in humans (Severe aortic stenosis; after transcatheter aortic valve implantation) (Baseline, POD1, POD2: systolic BP 130.7, 124.3, 132.2 mmHg; diastolic BP 66.0, 49.0, 65.0 mmHg).

    HumansSevere aortic stenosis; after transcatheter aortic valve implantationPostoperative days 1 and 234.2% malesn = 427

More on Blood pressure

Complications

upin humans1

1 study
  1. Transcatheter aortic valve implantation is associated with complications in humans (severe symptomatic aortic stenosis).

    Humanssevere symptomatic aortic stenosis

Frailty

downin humans1

1 study
  1. Frailty predicts transcatheter aortic valve implantation in humans (severe aortic stenosis referred for TAVI).

    Humanssevere aortic stenosis referred for TAVIn = 142

Heart failure

downin humans1HR 0.64

1 study
  1. Transcatheter aortic valve implantation is linked with a lower risk of heart failure in humans (symptomatic severe aortic stenosis) (HR 0.64, 95% CI 0.40-0.99).

    Humanssymptomatic severe aortic stenosis2-year

More on Heart failure

30-day VARC-2 composite endpoint

mixedin humans1

1 study
  1. Transcatheter aortic valve implantation is associated with 30-day VARC-2 composite endpoint in humans (high- and intermediate-risk women) (7% of cases).

    Humanshigh- and intermediate-risk womennew-generation devices30 daysfemalesn = 331

Mild paravalvular regurgitation

upin humans1

1 study
  1. Transcatheter aortic valve implantation is associated with mild paravalvular regurgitation in humans (Surgical high-risk severe aortic stenosis; compared with surgical aortic valve replacement) (29.6% versus 1.7%; P<0.001).

    HumansSurgical high-risk severe aortic stenosis; compared with surgical aortic valve replacementPerioperative

More on Mild paravalvular regurgitation

Pacemaker implantation

upin humans1

1 study
  1. Transcatheter aortic valve implantation is associated with pacemaker implantation in humans (Surgical high-risk severe aortic stenosis; compared with surgical aortic valve replacement) (17.5 (12/67) versus 0; P=0.008).

    HumansSurgical high-risk severe aortic stenosis; compared with surgical aortic valve replacement1 year

Rehospitalization

downin humans1

1 study
  1. Transcatheter aortic valve implantation is associated with rehospitalization in humans (Surgical high-risk severe aortic stenosis; compared with surgical aortic valve replacement) (3.0% versus 22.7%; P=0.005).

    HumansSurgical high-risk severe aortic stenosis; compared with surgical aortic valve replacement1 year

All 15

Funding

1 grant since 2020

Gouvernement du Canada | Canadian Institutes of Health ResearchCA$17.5K

How this record changed

  1. Summary written from the findings.

Latest

Dec 2025: 2Jan 2026: 5Feb 2026: 4Mar 2026: 5Apr 2026: 0May 2026: 1Jun 2026: 1Jul 2026: 1Aug 2026: 1Sep 2026: 0Oct 2026: 7Nov 2026: 330 papers in 12 months
AHA Scientific Sessions 2026 Abstract

Frailty predicted death better than age after valve replacement

Survival through seven years was 64.9% in frail patients versus 74.5% in those without frailty after a catheter-based aortic valve procedure.Survival through seven years was 64.9% in frail patients versus 74.5% in those without frailty after a catheter-based aortic valve procedure.

Cohort · 710 peopleBiomarkers