Cardiac xenotransplantation
2 papers5 findings
- 2 independent labs in 1 country
- Humans1
Outcomes
5End diastolic diameter
downin humans1
1 study
End diastolic diameter
downin humans1
Cardiac xenotransplantation decreases end diastolic diameter in humans (-40.2% (CI 20.3-64.1%)).
“From post-operative day (POD) 1 of xenotransplant to end-of-life, RVWT increased 80.9% (CI 95.6-118.5%) while EDD decreased 40.2% (CI 20.3-64.1%).”
Human trialin cardiac xenotransplant recipientsheartn = 2
AHA Scientific Sessions 2025 abstract3 Nov 2025
Right ventricular wall thickness
upin humans1
1 study
Right ventricular wall thickness
upin humans1
Cardiac xenotransplantation increases right ventricular wall thickness in humans (80.9% (CI 95.6-118.5%)).
“From post-operative day (POD) 1 of xenotransplant to end-of-life, RVWT increased 80.9% (CI 95.6-118.5%) while EDD decreased 40.2% (CI 20.3-64.1%).”
Human trialin cardiac xenotransplant recipientsheartn = 2
AHA Scientific Sessions 2025 abstract3 Nov 2025
Heart rate
no changein humans1
1 study
Heart rate
no changein humans1
Cardiac xenotransplantation has no effect on heart rate in humans (difference of 1.9±3.0, P=0.13).
“The average heart rate (HR) was similar between the 1 st and 2 nd xenotransplant with a HR difference of 1.9±3.0 (75.0±10.0bpm vs 73.1±16.7bpm, P=0.13)”
Human trial1st vs 2nd xenotransplant recipientheartn = 2
Comparison of baseline EKG parameters between the first and second Heart xenotransplant
AHA Scientific Sessions 2025 abstract3 Nov 2025
QT interval
upin humans1
1 study
QT interval
upin humans1
Cardiac xenotransplantation increases QT interval in humans (difference of 132.1±9.7, P<0.001).
“Similarly, the QT interval (ventricular repolarization) was significantly longer in the 1 st xenotransplant compared to the 2 nd, with a difference of 132.1±9.7 (509.0±51.0ms vs 376.9±42.4ms, P<0.001).”
Human trial1st vs 2nd xenotransplant recipientheartn = 2
Comparison of baseline EKG parameters between the first and second Heart xenotransplant
AHA Scientific Sessions 2025 abstract3 Nov 2025
PR interval
upin humans1
1 study
PR interval
upin humans1
Cardiac xenotransplantation increases PR interval in humans (difference of 55.2±6.2ms, P<0.001).
“The average PR interval was significantly longer in the 1 st xenotransplant compared to the 2 nd, with a difference of 55.2±6.2ms (212.0±20.0ms vs 156.8±32.5ms, P<0.001).”
Human trial1st vs 2nd xenotransplant recipientheartn = 2
Comparison of baseline EKG parameters between the first and second Heart xenotransplant
AHA Scientific Sessions 2025 abstract3 Nov 2025