There are 9 papers on ambulatory systolic blood pressure in aging research: 4 trials and 2 observational studies in people, 3 reviews.
9 papers study it24 more mention it6 findings
15 new papers in 30 daysSee all 33 papers on ambulatory systolic blood pressure
“models including daytime or nighttime systolic BP better predicted HF than those involving daytime or nighttime PP”
- Human trial4
- Humans2
Interventions
4Renal denervation
downin humans2
2 studies
Renal denervation
downin humans2
Renal denervation decreases ambulatory systolic blood pressure in humans (resistant or difficult-to-control treated hypertension; compared with sham control) (MD −3.54 mmHg; 95% CI −5.99 to −1.09).
“Compared with sham control, RDN significantly reduced ambulatory SBP in resistant/difficult-to-control treated hypertension”
Reviewresistant or difficult-to-control treated hypertension; compared with sham controlcatheter-basedn = 1,555
AHA Scientific Sessions 2026 abstract
Renal denervation decreases ambulatory systolic blood pressure in humans (resistant hypertension) (MD –8.7 mmHg, 95% CI –11.2 to –6.2).
“RDN significantly reduced 24-hour ASBP (MD –8.7 mmHg, 95% CI –11.2 to –6.2; p<0.0001; I 2 =31%).”
Reviewresistant hypertensionmedian follow-up 28 monthsn = 5,892
AHA Scientific Sessions 2026 abstract
Sleeve gastrectomy
downin humans1
1 study
Sleeve gastrectomy
downin humans1
Sleeve gastrectomy decreases ambulatory systolic blood pressure in humans (-10.5 mmHg).
“and in ABPM SBP 6.5 mmHg (p < 0.05)[1 W] and 10.5 mmHg (p < 0.05)[1 M]”
Human trial1 monthn = 40
Hypertension research : official journal of the Japanese Society of Hypertension
Mglide
downin humans1
1 study
Mglide
downin humans1
Mglide decreases ambulatory systolic blood pressure in humans (uncontrolled hypertension) (4.8 mm Hg lower (P=0.014)).
“The mGlide arm also had a 4.8 mm Hg (P=0.014) lower 24-hour average ambulatory SBP.”
Human trialuncontrolled hypertension6 monthsn = 395
mHealth Intervention to Improve Hypertension Care in High-Risk Patients
Hypertension (Dallas, Tex. : 1979)
Isometric handgrip training
no changein humans1
1 study
Isometric handgrip training
no changein humans1
Isometric handgrip training showed no clear effect on ambulatory systolic blood pressure in humans (p > 0.05).
“No differences were observed in 24-h ambulatory, daytime, and nighttime SBP and DBP in any group (p > 0.05).”
Human trialhome-based8 weeks
Journal of the American Geriatrics Society
Effects
1Heart failure prediction performance
upin humans1
1 study
Heart failure prediction performance
upin humans1
Ambulatory systolic blood pressure is linked with better heart failure prediction performance in humans (treated hypertension; compared with models using ambulatory pulse pressure) (P < 0.05).
“models including daytime or nighttime systolic BP better predicted HF than those involving daytime or nighttime PP”
Humanstreated hypertension; compared with models using ambulatory pulse pressure7.0 ± 4.0 yearsn = 1,314
High blood pressure & cardiovascular prevention : the official journal of the Italian Society of Hypertension