The European Respiratory Journal

Exercise test variation prevented all-age reference ranges

A retrospective analysis of 5,956 healthy people aged 6 to 83 found differences between testing sites too large to build reliable reference ranges.

Paper by Thomas Radtke, Luis Chávez, Lauren Duggan, +14 more authorsKarl Peter Sylvester · University of Zurich · Royal Papworth Hospital

Our read

Biomarkers
Studied:
Cross-sectional study of 5,956 healthy individuals aged between 6 and 83 years
The catch:
Testing equipment, exercise protocols, and averaging methods differed substantially between sites

Editor of record: Boris Djordjevic · AgingResearch.News

Follow @agingbrief

Researchers analyzed exercise-test data from 5,956 healthy people aged 6 to 83 in a retrospective observational study. The data came from 17 sites in Europe, North and South America, and Asia. The tests assessed the body’s response to increasingly demanding exercise. The team sought reference ranges for oxygen uptake at peak exercise and the highest workload reached, accounting for age, sex, height and weight.

Both measures varied substantially between people. Differences in peak oxygen uptake were linked to geographic region, testing equipment and how peak measurements were averaged. Accounting for these factors improved the models, but not enough to produce reliable reference ranges. The task force developed a framework for future data collection using strictly standardized testing protocols and centralized analysis.

Why it matters

Age-spanning reference ranges could help clinicians interpret exercise limitations as people grow older.

Caveats

The analysis combined previously collected data with substantial differences in testing methods between sites. It covered healthy people aged 6 to 83, not people with illness or those outside that age range.

Comments

Be the first to comment.