Cardiac resynchronization therapy defibrillator
Cardiac resynchronization therapy defibrillator has been studied in 7 papers since 2016: 7 observational studies in people. The newest paper, Oct 14, 2024: “Predictors of death without prior appropriate therapy in ICD recipients: the comorbidities, frailty and functional status (COMFFORT study)”.
7 papers study it3 findingsUpdated
See all 7 papers on cardiac resynchronization therapy defibrillator
At a glance
The findings reach people, from one lab or study. 2 independent labs in 2 countries.
“There were no significant differences in mortality between patients with CRT-D versus CRT-P (P = 0.3386).”
1 of its findings points the other way.
- 2 independent labs in 2 countries
- 1 finding against
- Funders: Abbott and 3 more
- 2 of 3 findings with company ties
- Humans7
What did studies of cardiac resynchronization therapy defibrillator find?
1Studies of cardiac resynchronization therapy defibrillator measured 1 outcome; the most studied are mortality (2 studies).
Mortality
no changein humans1downin humans1HR 0.9
2 studies
Mortality
no changein humans1downin humans1HR 0.9
Cardiac resynchronization therapy defibrillator was not clearly linked with mortality in patients undergoing CRT (P = 0.3386).
“There were no significant differences in mortality between patients with CRT-D versus CRT-P (P = 0.3386).”
Humansin patients undergoing CRTn = 285
International heart journal
Cardiac resynchronization therapy defibrillator is linked with lower mortality in humans (heart failure with reduced ejection fraction, compared with ICD alone) (HR 0.90, 95% CI 0.86-0.95).
“In the 2 oldest age strata, the hazard of death was lower in the CRT-D group (HR: 0.90; 95% CI: 0.86-0.95 and HR: 0.81; 95% CI: 0.72-0.90, respectively; P < 0.001)”
Humansheart failure with reduced ejection fraction, compared with ICD alone
JACC. Heart failure
What is cardiac resynchronization therapy defibrillator linked with?
1Studies link cardiac resynchronization therapy defibrillator with 1 measure, most often heart failure hospitalization (1 study).
Heart failure hospitalization
downin humans1HR 0.82
1 study
Heart failure hospitalization
downin humans1HR 0.82
Cardiac resynchronization therapy defibrillator is linked with a lower risk of heart failure hospitalization in humans (heart failure with reduced ejection fraction, compared with ICD alone) (HR 0.82, 95% CI 0.74-0.92).
“the hazard of heart failure hospitalization was lower for CRT-D vs ICD in the 85+ years age group (HR: 0.82; 95% CI: 0.74-0.92; P < 0.001).”
Humansheart failure with reduced ejection fraction, compared with ICD alone
JACC. Heart failure