AI-ECG age gap

There are 16 papers on AI-ECG age gap in aging research: 16 observational studies in people. The newest story, Nov 9, 2026: “Heart-test age gap linked to deaths after mitral valve surgery”.

Biomarker

16 papers study it40 findings

4 new papers in 30 daysSee all 16 papers on AI-ECG age gap

At a glance

A larger AI-ECG age gap is linked with dementia and worse cognition in UK Biobank participants, and with atrial fibrillation across human cohorts. It also predicts mortality in patients undergoing percutaneous coronary interventions. Bariatric surgery is associated with a lower gap after the first postoperative year, whereas within-person weight loss shows no clear link.

40 findings in 16 papers from 2023 to 2026, 10 of them since June 2026

“In the ECG-aged group, increased risks of new-onset AF were observed with hazard ratios (95% confidence intervals) of 2.50 (2.24-2.78), 1.89 (1.46-2.43), 1.90 (1.55-2.33), and 1.76 (1.67-1.86)”
Artificial intelligence-derived electrocardiographic aging and risk of atrial fibrillation: a multi-national studyEuropean heart journal2024doi:10.1093/eurheartj/ehae790
  • Humans16

Interventions

3

Bariatric surgery

downin humans1

1 study
  1. Bariatric surgery is linked with lower AI-ECG age gap in humans after the first postoperative year (-0.192 years/year (95% CI, -0.303 to -0.081)).

    Humansafter the first postoperative year

    Weight-loss surgery linked to later decline in heart-based age gap

    Obesity surgery

More on Bariatric surgery

Becoming socially isolated

upin humans1

1 study
  1. Becoming socially isolated is linked with higher AI-ECG age gap in humans (compared to being persistently connected) (β = +0.438 years, P = 0.012).

    Humanscompared to being persistently connected

More on Becoming socially isolated

Social isolation

upin humans1

1 study
  1. Social isolation is linked with higher AI-ECG age gap in humans (compared to being persistently connected) (β = +0.412 years, P < 0.001).

    Humanscompared to being persistently connected

More on Social isolation

Effects

3

Operative mortality

no changein humans1

1 study
  1. AI-ECG age gap was not clearly linked with operative mortality in humans After isolated coronary artery bypass grafting; adjusted for chronological age and sex.

    HumansAfter isolated coronary artery bypass grafting; adjusted for chronological age and sexn = 9,938

General cognitive ability

downin humans1

1 study
  1. AI-ECG age gap is linked with worse general cognitive ability in humans (UK Biobank) (−0.11 vs −0.02 per 5-year interval).

    HumansUK Biobank5-year intervaln = 42,571

    Older-than-expected heart age linked to dementia risk

    ESC Congress 2026 abstract

Cognitive function

downin humans1

1 study
  1. AI-ECG age gap is linked with worse cognitive function in humans (UK Biobank).

    HumansUK Biobankn = 42,571

    Older-than-expected heart age linked to dementia risk

    ESC Congress 2026 abstract

Upstream

4

PKP2-related arrhythmogenic cardiomyopathy

no changein humans1

1 study
  1. PKP2-related arrhythmogenic cardiomyopathy was not clearly linked with AI-ECG age gap in humans (PKP2-related arrhythmogenic cardiomyopathy compared with TTN-related cardiomyopathy) (3.8±10.7 vs. 6.1±10.5 years; p=0.151).

    HumansPKP2-related arrhythmogenic cardiomyopathy compared with TTN-related cardiomyopathy

More on PKP2-related arrhythmogenic cardiomyopathy

Weight loss

no changein humans1

1 study
  1. Weight loss was not clearly linked with AI-ECG age gap in humans within-person weight change (+0.117 years per 10 kg (P=.084)).

    Humanswithin-person weight change

    Weight-loss surgery linked to later decline in heart-based age gap

    Obesity surgery

Late gadolinium enhancement

no changein humans1

1 study
  1. Late gadolinium enhancement was not clearly linked with AI-ECG age gap in humans (genetic ACM/DCM) (6.99 vs. 7.94 years; p=0.831).

    Humansgenetic ACM/DCMheartn = 538

More on Late gadolinium enhancement

Heart failure

upin humans1

1 study
  1. Heart failure is linked with higher AI-ECG age gap in humans (compared with healthy controls).

    Humanscompared with healthy controls

More on Heart failure

Associations

18

Atrial fibrillation

upin humans3HR 1.37–2.5

3 studies
  1. AI-ECG age gap is linked with a higher risk of atrial fibrillation in humans (incident AF) (HR 1.37, 95% CI: 1.24-1.51).

    Humansincident AFn = 39,478

  2. AI-ECG age gap is linked with a higher risk of atrial fibrillation in humans (GRS-based Mendelian randomization; per 1-SD increase in AI-ECG age gap) (OR 1.06, 95% CI 1.01–1.12 per 1-SD increase).

    HumansGRS-based Mendelian randomization; per 1-SD increase in AI-ECG age gap

  3. AI-ECG age gap is associated with atrial fibrillation in humans (Observational analysis; per 1-SD increase in AI-ECG age gap) (HR 1.43, 95% CI 1.29–1.59 per 1-SD increase).

    HumansObservational analysis; per 1-SD increase in AI-ECG age gap

  4. AI-ECG age gap is linked with a higher risk of atrial fibrillation in humans (HR 1.76 to 2.50 across cohorts).

    Humans

More on Atrial fibrillation

Mortality

upin humans3HR 1.07–1.53

3 studies
  1. AI-ECG age gap predicts mortality in humans (HR 1.53, 95% CI 1.11-2.09 per 5-year higher age gap).

    HumansObstructive hypertrophic cardiomyopathy undergoing septal reduction therapy; per 5-year higher preoperative AI-ECG age gap70.5% femalesn = 190

    Age gap linked to death after septal reduction in patients 75+

    AHA Scientific Sessions 2026 abstract
  2. AI-ECG age gap is associated with mortality in humans following repeat aortic valve replacement.

    Humansfollowing repeat aortic valve replacement

    Heart-test age gap linked to deaths after repeat valve replacement

    The Journal of thoracic and cardiovascular surgery
  3. AI-ECG age gap predicts mortality in humans (patients undergoing percutaneous coronary interventions) (HR 1.07, 95% CI 1.04-1.10).

    Humanspatients undergoing percutaneous coronary interventionsmedian follow-up of 2.61 yearsn = 535

Postoperative atrial fibrillation

upin humans2OR 1.08–1.32

2 studies
  1. AI-ECG age gap is associated with postoperative atrial fibrillation in humans Following mitral valve surgery (Adjusted OR 1.08 per 5-year increase, 95% CI 1.03–1.12).

    HumansFollowing mitral valve surgeryPer 5-year increase in AI-ECG age gapn = 5,435

    Heart-test age gap linked to deaths after mitral valve surgery

    AHA Scientific Sessions 2026 abstract
  2. AI-ECG age gap is associated with postoperative atrial fibrillation in humans (OR 1.32, 95% CI 1.07-1.61).

    HumansAfter isolated coronary artery bypass grafting; age gap >=+10 versus -5 to +5 years; adjusted for chronological age and sexn = 9,938

More on Postoperative atrial fibrillation

Long-term all-cause mortality

upin humans2HR 1.12–2.41

2 studies
  1. AI-ECG age gap is associated with long-term all-cause mortality in humans Following mitral valve surgery (Adjusted HR 1.12 per 5-year increase, 95% CI 1.07–1.16).

    HumansFollowing mitral valve surgeryPer 5-year increase in AI-ECG age gapMedian follow-up of 8.5 yearsn = 5,435

    Heart-test age gap linked to deaths after mitral valve surgery

    AHA Scientific Sessions 2026 abstract
  2. AI-ECG age gap is associated with long-term all-cause mortality in humans (HR 2.41, 95% CI 2.11-2.75).

    HumansAfter isolated coronary artery bypass grafting; age gap >=+10 versus -5 to +5 years; adjusted for chronological age and sexMedian follow-up 14.6 yearsn = 9,938

Major adverse cardiac and cerebrovascular events

downin humans1upin humans1HR 0.46–1.13

1 study
  1. AI-ECG age gap is linked with a lower risk of major adverse cardiac and cerebrovascular events in humans (age gap < -6 years) (HR 0.46).

    Humansage gap < -6 yearsn = 40,953

  2. AI-ECG age gap is linked with a higher risk of major adverse cardiac and cerebrovascular events in humans (HR = 1.13, 95% CI: 1.11–1.14).

    Humansn = 40,953

More on Major adverse cardiac and cerebrovascular events

Operative mortality

upin humans1OR 1.48

1 study
  1. AI-ECG age gap is associated with operative mortality in humans Following mitral valve surgery (Adjusted OR 1.48, 95% CI 1.02–2.14).

    HumansFollowing mitral valve surgeryn = 5,435

    Heart-test age gap linked to deaths after mitral valve surgery

    AHA Scientific Sessions 2026 abstract

Hospital length of stay

upin humans1

1 study
  1. AI-ECG age gap is associated with hospital length of stay in humans Following mitral valve surgery.

    HumansFollowing mitral valve surgeryn = 5,435

    Heart-test age gap linked to deaths after mitral valve surgery

    AHA Scientific Sessions 2026 abstract

Blood transfusion

upin humans1OR 1.05

1 study
  1. AI-ECG age gap is associated with blood transfusion in humans Following mitral valve surgery (Adjusted OR 1.05, 95% CI 1.01–1.10).

    HumansFollowing mitral valve surgeryn = 5,435

    Heart-test age gap linked to deaths after mitral valve surgery

    AHA Scientific Sessions 2026 abstract

More on Blood transfusion

Permanent device requirement

upin humans1OR 2.38

1 study
  1. AI-ECG age gap is associated with permanent device requirement in humans (OR 2.38, 95% CI 1.04-5.48).

    HumansAfter isolated coronary artery bypass grafting; age gap >=+10 versus -5 to +5 years; adjusted for chronological age and sexn = 9,938

Septal myectomy

downin humans1

1 study
  1. Septal myectomy is associated with AI-ECG age gap in humans (Obstructive hypertrophic cardiomyopathy; compared with alcohol septal ablation).

    HumansObstructive hypertrophic cardiomyopathy; compared with alcohol septal ablation0-7 days, 8-365 days, and >365 days following the proceduren = 189

    Age gap linked to death after septal reduction in patients 75+

    AHA Scientific Sessions 2026 abstract

More on Septal myectomy

All 18

How this record changed

  1. Summary rewritten as its findings changed.

    As it read before

    A human study links AI-ECG age gap to mortality and postoperative outcome markers following repeat aortic valve replacement; another links it to increased risk of incident atrial fibrillation.

  2. Summary written from the findings.

Latest

Dec 2025: 1Jan 2026: 0Feb 2026: 0Mar 2026: 1Apr 2026: 0May 2026: 0Jun 2026: 1Jul 2026: 0Aug 2026: 0Sep 2026: 3Oct 2026: 3Nov 2026: 312 papers in 12 months
AHA Scientific Sessions 2026 Abstract

Heart-test age gap linked to deaths after mitral valve surgery

Each five-year increase in the gap between heart-recording age estimates and actual age was linked to a 12% higher relative risk of death after surgery.Each five-year increase in the gap between heart-recording age estimates and actual age was linked to a 12% higher relative risk of death after surgery.

Cohort · 5,435 peopleBiomarkers
AHA Scientific Sessions 2026 Abstract

Age gap linked to death after septal reduction in patients 75+

Each five-year higher gap between age estimated from heart electrical recordings and actual age was associated with a 53% higher relative risk of death.Each five-year higher gap between age estimated from heart electrical recordings and actual age was associated with a 53% higher relative risk of death.

Cohort · 190 peopleBiomarkers
JTCVS Open

Higher heart age gap linked to rhythm problems after bypass

An observational study of 9,938 adults linked a higher computer-estimated heart age gap to rhythm problems and long-term death risk; median follow-up was 14.6 years.An observational study of 9,938 adults linked a higher computer-estimated heart age gap to rhythm problems and long-term death risk; median follow-up was 14.6 years.

Cohort · 9,938 peopleBiomarkers
ESC Congress 2026 Abstract

Older-than-expected heart age linked to dementia risk

Dementia hazard ratios—a measure of relative risk—were 2.56 in UK Biobank and 1.19 in Severance versus participants without accelerated heart aging.Dementia hazard ratios—a measure of relative risk—were 2.56 in UK Biobank and 1.19 in Severance versus participants without accelerated heart aging.

Cohort studyDementia
The Journal of Thoracic and Cardiovascular Surgery

Heart-test age gap linked to deaths after repeat valve replacement

An age estimate above actual age was linked to a higher relative rate of death, with a reported hazard ratio of 1.20.An age estimate above actual age was linked to a higher relative rate of death, with a reported hazard ratio of 1.20.

Cohort studyBiomarkers
Obesity Surgery

Weight-loss surgery linked to later decline in heart-based age gap

The age gap fell 0.192 years per year after the first year following surgery, compared with no clear change during that first year.The age gap fell 0.192 years per year after the first year following surgery, compared with no clear change during that first year.

Cohort · 2,380 peopleInterventions

See all 16 papers on AI-ECG age gap