Osteoporosis Self-Assessment Tool
7 papers study it36 more mention it8 findings
1 new paper in 30 daysSee all 43
- Humans7
Associations
4Osteoporosis
upin humans4
4 studies
Osteoporosis
upin humans4
Osteoporosis Self-Assessment Tool predicts osteoporosis in humans (AUC 0.7339 (95% CI, 0.7121-0.7556)).
“The AUCs were 0.7339 (95% CI, 0.7121-0.7556) for OST”
Humansmalesn = 2,824
Frontiers in endocrinology
Osteoporosis Self-Assessment Tool predicts osteoporosis in humans (AUC 0.79 to 0.85).
“For discrimination of femoral neck osteoporosis, AUC values were excellent for OST (range, 0.79 [95% CI, 0.65-0.93] to 0.85 [95% CI, 0.74-0.96]), higher for OST than FRAX”
Humansfemoral neckfemalesn = 4,607
JAMA internal medicine
Osteoporosis Self-Assessment Tool predicts osteoporosis in humans (sensitivity 86.49% at cutoff 2.5).
“To differentiate normal participants from those with osteoporosis, the cutoff value with optimal sensitivity was 2.5. At such a cutoff value, the test sensitivity was 86.49%.”
Humanscutoff 2.5femalesn = 2,969
Cureus
Osteoporosis Self-Assessment Tool predicts osteoporosis in humans (AUC 0.702, sensitivity 95.7%, specificity 33.6%).
“OST index ≤2 predicted osteoporosis with a sensitivity of 95.7% and a specificity of 33.6% and an area under the curve for a receiver operating characteristic curve of 0.702.”
HumansOSTA index <= 2malesn = 257
Journal of clinical densitometry : the official journal of the International Society for Clinical Densitometry
Mortality
upin humans1downin humans1HR 0.66
2 studies
Mortality
upin humans1downin humans1HR 0.66
Osteoporosis Self-Assessment Tool is associated with mortality in humans (aOR 2.08, 95% CI 1.44-3.01).
“OST Tertile 3 remained independently associated with increased in-hospital mortality (adjusted odds ratio 2.08; 95 % CI, 1.44-3.01) compared with Tertile 1.”
Humansacute myocardial infarction
International journal of cardiology. Cardiovascular risk and prevention
Osteoporosis Self-Assessment Tool lowers the risk of mortality in humans (HR 0.66, 95% CI 0.48-0.90).
“Multivariate analysis revealed that OST tertiles 3 was associated with decreased risk of all-cause mortality (hazard ratio, 0.66; 95% confidence interval, 0.48-0.90)”
Humansmen undergoing transcatheter aortic valve replacementmalesn = 1,339
Cardiovascular intervention and therapeutics
Major osteoporotic fractures
mixedin humans1
1 study
Major osteoporotic fractures
mixedin humans1
Osteoporosis Self-Assessment Tool predicts major osteoporotic fractures in humans (AUC 0.53 to 0.62).
“The AUC values for OST were 0.62 (95% CI, 0.56-0.69) for Asian, 0.53 (95% CI, 0.50-0.57) for Black, 0.58 (95% CI, 0.54-0.62) for Hispanic, and 0.55 (95% CI, 0.54-0.56) for White women.”
Humans10 yearsfemalesn = 67,169
JAMA internal medicine
Osteopenia
upin humans1
1 study
Osteopenia
upin humans1
Osteoporosis Self-Assessment Tool predicts osteopenia in humans (sensitivity 81.04% at cutoff 3.5).
“To differentiate normal individuals from those with osteopenia, the cutoff value with optimal sensitivity was 3.5. At such a cutoff value, the test sensitivity was 81.04%.”
Humanscutoff 3.5femalesn = 2,969
Cureus