Wearable sensor
Wearable sensor has been studied in 37 papers since 2017: 2 trials and 16 observational studies in people, 13 reviews; 14 in the past year. The newest paper, Sep 24, 2026: “DIGITAL MENOPAUSE CARE AS AN EMERGING FemTech FIELD: A REVIEW OF MOBILE APPLICATIONS, WEARABLE SENSORS, AND AI-BASED SYMPTOM MONITORING IN PERI- AND POSTMENOPAUSAL HEALTH”.
37 papers study it8 findingsUpdated
See all 37 papers on wearable sensor
At a glance
The findings reach people, from one lab or study. 7 independent labs in 5 countries.
“Spearman's rank correlation coefficient indicated strong agreement between the sensor-obtained step-count and that of the criterion measure in both age groups, in all mobility tests.”
None of its findings points the other way.
- 7 independent labs in 5 countries
- Funders: Knowledge Foundation and 7 more
- Human trial2
- Humans16
- In silico1
What did studies of wearable sensor find?
1Studies of wearable sensor measured one outcome, gait assessment.
Gait assessment
upin humans1
1 study
Gait assessment
upin humans1
Wearable sensor improves gait assessment in humans (dementia).
Reviewdementia
What is wearable sensor linked with?
7Studies link wearable sensor with 7 measures, among them fall risk, near falls and pre-frail or frail status by CGA-FI.
Fall risk
upin humans1
1 study
Fall risk
upin humans1
Wearable sensor predicts fall risk in humans (AUC 0.60-0.84).
Review
Near falls
upin humans1
1 study
Near falls
upin humans1
Wearable sensor predicts near falls in humans (sensitivities of 80%-98%).
Review
Pre-frail or frail status by CGA-FI
upin humans1
1 study
Pre-frail or frail status by CGA-FI
upin humans1
Wearable sensor predicts pre-frail or frail status by CGA-FI in humans (AUC 0.78).
Humans10 daysn = 44
Pre-frail or frail status by FFP
upin humans1
1 study
Pre-frail or frail status by FFP
upin humans1
Wearable sensor predicts pre-frail or frail status by FFP in humans (AUC 0.81).
Humans10 daysn = 44
Fall risk assessment
upin humans1
1 study
Fall risk assessment
upin humans1
Wearable sensor predicts fall risk assessment in humans (community-dwelling older adults).
Reviewcommunity-dwelling older adults
Step-count criterion measure
upin humans1
1 study
Step-count criterion measure
upin humans1
Wearable sensor is associated with step-count criterion measure in humans during a Timed Up and Go test under different conditions.
Human trialduring a Timed Up and Go test under different conditions
Fall risk classification
upin humans1
1 study
Fall risk classification
upin humans1
Wearable sensor predicts fall risk classification in older adults (mostly fallers/non-fallers) (AUC >= 0.74, accuracy >= 84%).
Reviewin older adults (mostly fallers/non-fallers)
Funding
7 grants since 2018National Institute on Aging$2.1MNational Science Foundation$1.2MDefense Health Agency$2.5M
National Institute on AgingBiosensics$1.2M2023–2027
Defense Health AgencyBiosensics$2.5M2024–2028
Wearable sensor platform for low-impact, balanced-based, aerobic training
Natural Sciences and Engineering Research CouncilQueen's UniversityCA$20K2023–2024
The association of wearable sensor measures of time use with cardiovascular disease
UKRI | Medical Research CouncilUniversity of Oxford2018–2022
National Institute on AgingWearifi$343K2018–2020
National Science FoundationColumbia Univ New York Morningside$272K2019–2022
National Science FoundationThe Trustees of the Stevens Institute of Technology$927K2019–2024
Contains public sector information licensed under the Open Government Licence v3.0.