Proximal femoral nail anti-rotation
Proximal femoral nail anti-rotation has been studied in 6 papers since 2017: 6 observational studies in people. The newest paper, Aug 11, 2025: “Comparison of proximal femoral universal nail and proximal femoral nail anti-rotation internal fixation for older patients with intertrochanteric femoral fracture: a retrospective cohort study”.
6 papers study it4 findingsUpdated
“bleeding loss was (153.33 ± 59.96) mL and (335.31 ± 90.87) mL(P < 0.05)”
None of its findings points the other way.
- 2 independent labs in 1 country
- Humans6
What did studies of Proximal femoral nail anti-rotation find?
3Studies of Proximal femoral nail anti-rotation measured 3 outcomes; the most studied are postoperative complications (1 study), harris score (1) and bleeding loss (1).
Postoperative complications
no changein humans1
1 study
Postoperative complications
no changein humans1
Proximal femoral nail anti-rotation has no effect on postoperative complications in humans.
“There was no significant difference in postoperative complications between the two groups (P > 0.05).”
Human trialintertrochanteric fractures
Research SquarePreprint
Harris score
upin humans1
1 study
Harris score
upin humans1
Proximal femoral nail anti-rotation improves harris score in humans (73.20 vs 68.91 points).
“the Harris scores were (73.20 ± 6.56) points and (68.91 ± 8.15) points (P < 0.05)”
Human trialintertrochanteric fractures
Research SquarePreprint
Bleeding loss
downin humans1
1 study
Bleeding loss
downin humans1
Proximal femoral nail anti-rotation decreases bleeding loss in humans (153.33 vs 335.31 mL).
“bleeding loss was (153.33 ± 59.96) mL and (335.31 ± 90.87) mL(P < 0.05)”
Human trialintertrochanteric fractures
Research SquarePreprint
What is Proximal femoral nail anti-rotation linked with?
1Studies link Proximal femoral nail anti-rotation with 1 measure, most often intraoperative blood loss (1 study).
Intraoperative blood loss
downin humans1
1 study
Intraoperative blood loss
downin humans1
Proximal femoral nail anti-rotation is associated with intraoperative blood loss in humans.
“The incision length, operation time, and intraoperative blood loss of group A were significantly less than those of groups B and C”
HumansFemoral intertrochanteric fracture; compared with locking compression plate and artificial femoral head replacement
Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery