Anti-biofilm antibiotics

Anti-biofilm antibiotics has been studied in 1 paper since 2024: 1 observational study in people. The newest paper, Oct 1, 2024: “"Implant-associated infection after hip fracture surgery in elderly patients: Risk factors and mortality"”.

Intervention

1 paper studies it2 findingsUpdated

See all 1 papers on anti-biofilm antibiotics

At a glance

The findings reach people, from one lab or study. 1 lab in 1 country.

“Receiving anti-biofilm antibiotics for more than 2 weeks was associated with less treatment failure (OR:0.32; [95 %CI: 0.13-0.80])”
"Implant-associated infection after hip fracture surgery in elderly patients: Risk factors and mortality"Injury2024doi:10.1016/j.injury.2024.111756

None of its findings points the other way.

Humans: a single group. Cells, worms or flies and mice: nothing yet.
  • 1 lab in 1 country
  • Funders: Australian Research Council and 1 more
  • Humans1

What did studies of anti-biofilm antibiotics find?

1

Studies of anti-biofilm antibiotics measured one outcome, implant-related infection.

Implant-related infection

downin humans1OR 0.32

1 study
  1. Anti-biofilm antibiotics are linked with lower implant-related infection in humans (implant-related infection following hip fracture) (OR 0.32, 95% CI 0.13-0.80).

    “Receiving anti-biofilm antibiotics for more than 2 weeks was associated with less treatment failure (OR:0.32; [95 %CI: 0.13-0.80])”

    Humansimplant-related infection following hip fracture>2 weeks

    "Implant-associated infection after hip fracture surgery in elderly patients: Risk factors and mortality"

    Injury

More on Implant-related infection

What is anti-biofilm antibiotics linked with?

1

Studies link anti-biofilm antibiotics with mortality.

Mortality

downin humans1OR 0.22

1 study
  1. Anti-biofilm antibiotics are linked with a lower risk of mortality in humans (implant-related infection following hip fracture) (OR 0.22, 95% CI 0.08-0.60).

    “Receiving anti-biofilm antibiotics for more than 2 weeks was associated with less treatment failure (OR:0.32; [95 %CI: 0.13-0.80]) and 12-month mortality (OR:0.22 [95 %CI: 0.08-0.60]).”

    Humansimplant-related infection following hip fracture>2 weeks

    "Implant-associated infection after hip fracture surgery in elderly patients: Risk factors and mortality"

    Injury

Latest