There are 63 papers on hip dislocation in aging research: 11 trials and 45 observational studies in people, 7 reviews.
1 new paper in 30 daysSee all 69 papers on hip dislocation
“Hip instability or dislocation occurred in 34 patients (4.7%) assigned to total hip arthroplasty and 17 patients (2.4%) assigned to hemiarthroplasty”
- Human trial11
- Humans45
Interventions
6Dual-mobility total hip arthroplasty
no changein humans1OR 0.34
1 study
Dual-mobility total hip arthroplasty
no changein humans1OR 0.34
Dual-mobility total hip arthroplasty was not clearly linked with hip dislocation in humans (displaced femoral neck fractures) (OR 0.34, 95% CI: 0.06-1.96).
Humansdisplaced femoral neck fractures2 years
Anterior approach
downin humans1
1 study
Anterior approach
downin humans1
Anterior approach is linked with lower hip dislocation in humans (1 anterior vs 3 posterior dislocations; P=.037).
HumansTotal hip arthroplasty for displaced femoral neck fracture; compared with posterior approachanterior approachhipn = 76
Free rehabilitation
no changein humans1
1 study
Free rehabilitation
no changein humans1
Free rehabilitation showed no clear effect on hip dislocation in humans (One patient in each group had dislocation(s)).
Human trialAfter hemiarthroplasty using a direct lateral approach; compared with rehabilitation precautions and mandatory assistive equipmenthip joint6 monthsn = 394
Total hip arthroplasty with dual mobility cup
downin humans1
1 study
Total hip arthroplasty with dual mobility cup
downin humans1
Total hip arthroplasty with dual mobility cup decreases hip dislocation in humans (Dementia and displaced femoral neck fracture; compared with bipolar hemiarthroplasty) (0% versus 16.6% with bipolar hemiarthroplasty; p = 0.019).
Human trialDementia and displaced femoral neck fracture; compared with bipolar hemiarthroplastydual mobility cuphip1 year
Total hip replacement
downin humans1
1 study
Total hip replacement
downin humans1
Total hip replacement is linked with lower hip dislocation in humans (acute femoral neck fractures; comparison with prior studies) (No dislocations in the first 3 years; 3 late dislocations).
Humansacute femoral neck fractures; comparison with prior studies40-mm and 44-mm femoral headship joint5 yearsn = 391
Total hip arthroplasty with a dual mobility cup
no changein humans1
1 study
Total hip arthroplasty with a dual mobility cup
no changein humans1
Total hip arthroplasty with a dual mobility cup was not clearly linked with hip dislocation in humans (Displaced intracapsular femoral neck fractures; compared with bipolar hemiarthroplasty).
HumansDisplaced intracapsular femoral neck fractures; compared with bipolar hemiarthroplastyn = 168
Associations
9Total hip arthroplasty
upin humans3HR 2
3 studies
Total hip arthroplasty
upin humans3HR 2
Total hip arthroplasty raises the risk of hip dislocation in humans (displaced femoral neck fracture, compared with hemiarthroplasty) (HR 2.00, 99% CI 0.97 to 4.09).
Human trialdisplaced femoral neck fracture, compared with hemiarthroplastyhip24 months
Total hip arthroplasty raises the risk of hip dislocation in humans (femoral neck fracture).
Reviewfemoral neck fracture
Total hip arthroplasty raises the risk of hip dislocation in humans (compared with hemiarthroplasty).
Reviewcompared with hemiarthroplastyhipfirst three years
Dual-mobility total hip arthroplasty
downin humans2RR 0.3
2 studies
Dual-mobility total hip arthroplasty
downin humans2RR 0.3
Dual-mobility total hip arthroplasty is associated with hip dislocation in humans (hip fracture; compared with standard total hip arthroplasty) (0 dislocations versus 4 with standard THA).
Humanship fracture; compared with standard total hip arthroplastyhip
Dual-mobility total hip arthroplasty lowers the risk of hip dislocation in humans (Femoral neck fractures; compared with bipolar hemiarthroplasty) (RR 0.3; 95% CI 0.17 to 0.53).
ReviewFemoral neck fractures; compared with bipolar hemiarthroplastyhip
Superpath approach
downin humans1
1 study
Superpath approach
downin humans1
Superpath approach is linked with a lower risk of hip dislocation in humans (femoral neck fractures with high dislocation risk).
Humansfemoral neck fractures with high dislocation riskn = 81
Piriformis-sparing approach
downin humans1
1 study
Piriformis-sparing approach
downin humans1
Piriformis-sparing approach lowers the risk of hip dislocation in humans (femoral neck fractures undergoing hemiarthroplasty) (0% vs 4.7%, P = .004).
Human trialfemoral neck fractures undergoing hemiarthroplasty24-60 monthsn = 321
Cementless total hip arthroplasty
upin humans1
1 study
Cementless total hip arthroplasty
upin humans1
Cementless total hip arthroplasty is linked with a higher risk of hip dislocation in humans (1.2% vs 1.8%).
Humans30 days
Hemiarthroplasty
upin humans1
1 study
Hemiarthroplasty
upin humans1
Hemiarthroplasty is associated with hip dislocation in humans After fragility femoral neck fracture; compared with lateral approach (Four (3.4%) dislocated hips versus none).
HumansAfter fragility femoral neck fracture; compared with lateral approachposterior approachhip1 yearn = 269
Direct anterior approach
downin humans1
1 study
Direct anterior approach
downin humans1
Direct anterior approach lowers the risk of hip dislocation in humans (compared to posterior capsular approaches for hemiarthroplasty).
Reviewcompared to posterior capsular approaches for hemiarthroplasty
Direct lateral hip arthroplasty approach
downin humans1
1 study
Direct lateral hip arthroplasty approach
downin humans1
Direct lateral hip arthroplasty approach is linked with a lower risk of hip dislocation in humans (Displaced femoral neck fracture; compared with posterolateral approach) (Dislocation rate 4% versus 13%).
HumansDisplaced femoral neck fracture; compared with posterolateral approachhipMean follow-up 25 months70% womensn = 362
Surgery
upin humans1
1 study
Surgery
upin humans1
Surgery is associated with hip dislocation in humans (proximal femoral fracture in centenarians) (n=3).
Humansproximal femoral fracture in centenarianshipn = 39