Hypoattenuated leaflet thickening

There are 4 papers on hypoattenuated leaflet thickening in aging research: 1 trial and 2 observational studies in people, 1 review.

Disease

4 papers study it3 findings

1 new paper in 30 daysSee all 4 papers on hypoattenuated leaflet thickening

“HALT was linked with greater WMH burden, but did not carry an increased risk of cognitive decline or mortality over a 3.1-year follow-up”
Subclinical leaflet thrombosis after transcatheter aortic valve implantation is associated with silent brain injury on brain magnetic resonance imagingEuropean heart journal. Cardiovascular Imaging2022doi:10.1093/ehjci/jeac191
  • Human trial1
  • Humans2

Interventions

1

Tirzepatide

downin humans1

1 study
  1. Tirzepatide decreases hypoattenuated leaflet thickening in obese patients undergoing transfemoral TAVR, assessed at 6 months (8.4% vs 21.6%; p = 0.002).

    “tirzepatide therapy significantly reduced HALT incidence (8.4% vs 21.6%, p = 0.002)”

    Human trialin obese patients undergoing transfemoral TAVR, assessed at 6 months6 months

    Tirzepatide therapy reduces subclinical leaflet thrombosis and paravalvular leak after transcatheter aortic valve replacement in obese patients: The TAVR-MET trial

    Cardiovascular revascularization medicine : including molecular interventions

More on Tirzepatide

Effects

1

Mortality

no changein humans1HR 0.86

1 study
  1. Hypoattenuated leaflet thickening was not clearly linked with mortality in humans following transcatheter aortic valve implantation (HR 0.86, 95% CI 0.202–3.687; P = 0.84).

    “HALT was linked with greater WMH burden, but did not carry an increased risk of cognitive decline or mortality over a 3.1-year follow-up”

    Humansfollowing transcatheter aortic valve implantation3.1 years

    Subclinical leaflet thrombosis after transcatheter aortic valve implantation is associated with silent brain injury on brain magnetic resonance imaging

    European heart journal. Cardiovascular Imaging

Associations

1

New white matter hyperintensity volume

upin humans1

1 study
  1. Hypoattenuated leaflet thickening is associated with new white matter hyperintensity volume in humans following transcatheter aortic valve implantation (β 0.72, 95% CI 0.2–1.39; P = 0.009).

    “In uni- and multivariate analysis, HALT was associated with new WMH volume (beta: 0.72; 95%CI: 0.2-1.39; P = 0.009).”

    Humansfollowing transcatheter aortic valve implantationbrain6 monthsn = 91

    Subclinical leaflet thrombosis after transcatheter aortic valve implantation is associated with silent brain injury on brain magnetic resonance imaging

    European heart journal. Cardiovascular Imaging

More on New white matter hyperintensity volume

Trial sponsors

Latest

Dec 2025: 0Jan 2026: 0Feb 2026: 0Mar 2026: 1Apr 2026: 0May 2026: 0Jun 2026: 0Jul 2026: 0Aug 2026: 0Sep 2026: 0Oct 2026: 0Nov 2026: 12 papers in 12 months