medRxiv

Automated tool measures muscle and fat from routine CT scans

In held-out scans, muscle area measurements averaged 1.35 square centimeters above radiologist-corrected labels at the third lumbar vertebra.

Paper by S. Hanaoka, W. Gonoi, S. Inui, +11 more authorsO. Abe · Department of Radiology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan

Our read

Biomarkers
Studied:
Preprint: study in people

Editor of record: Boris Djordjevic · AgingResearch.News

Follow @agingbrief

Routine computed tomography (CT) scans from five single-center datasets, totaling 4,986 scan series, were used in a development-and-validation study of an automated muscle-and-fat measurement tool. The tool located two spinal levels in the lower back and rejected levels outside the scan. It also adjusted measurements to estimated values without contrast dye.

Validation against radiologist-corrected labels used 2,025 scan series. Muscle area measurements at the third lumbar vertebra closely matched the reference. Contrast adjustment brought muscle measurements closer to those from scans taken without contrast during the same examination. In 2,006 patients after curative cancer surgery, automatically measured low muscle mass improved predictions of cancer-specific and overall survival.

Why it matters

Routine scans could support studies of body composition and age assessment without manual measurements. Alongside its main measurements, the tool also estimated muscle and marrow age.

Caveats

Validation used held-out portions of single-center datasets, leaving performance in broader clinical settings open. The work is a preprint and has not been peer-reviewed.

Comments

Be the first to comment.

The paper

Deep-learning body composition analysis of routine CT robust to scan range, slice order and contrast phase

S. Hanaoka, W. Gonoi, S. Inui, +11 more authorsO. Abe

Department of Radiology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan

medRxiv, Nov 15, 2026, Open access, CC BY-NC, Preprint, not yet peer-reviewed

doi.org/10.64898/2026.11.12.26367971