Intersection-point-height

There are 2 papers on intersection-point-height in aging research: 1 observational study in people.

Biomarker

2 papers study it4 findings

See all 2 papers on intersection-point-height

“Summative Intersection Point Height exhibited strong convergent validity with Trail Making Tests A and B (rho = 0.49, p < 0.001)”
Reliability and validity of the force intersection point in the assessment of human quiet standing balanceHuman movement science2024doi:10.1016/j.humov.2024.103239
  • Humans1

Interventions

1

Force plate

downin silico1upin silico1

1 study
  1. Force plate impairs intersection-point-height in silico (frontal-plane quiet standing).

    “low signal strength prevented precise readings in the frontal plane. Thus, the tested device only marginally met the precision required for quiet-standing analysis”

    In silicofrontal-plane quiet standinglaboratory-grade portable force plate

    Can force-plate measurement be trusted for balance diagnostics? Frequency-domain force-plate performance assessment for quiet-standing studies

    bioRxivPreprint

  2. Force plate improves intersection-point-height in silico (sagittal-plane quiet standing at lowest frequencies).

    “While the device successfully captured sagittal-plane intersection-point-height at the lowest frequencies, low signal strength prevented precise readings in the frontal plane.”

    In silicosagittal-plane quiet standing at lowest frequencieslaboratory-grade portable force plate

    Can force-plate measurement be trusted for balance diagnostics? Frequency-domain force-plate performance assessment for quiet-standing studies

    bioRxivPreprint

More on Force plate

Associations

2

Mini-Balance Evaluation Systems Test

downin humans1

1 study
  1. Intersection-point-height is associated with Mini-Balance Evaluation Systems Test in humans (rho = -0.47, p < 0.001).

    “and the Mini-Balance Evaluation Systems Test (rho = -0.47, p < 0.001).”

    Humansn = 146

    Reliability and validity of the force intersection point in the assessment of human quiet standing balance

    Human movement science

More on Mini-Balance Evaluation Systems Test

Trail Making Test

upin humans1

1 study
  1. Intersection-point-height is associated with Trail Making Test in humans (rho = 0.49, p < 0.001).

    “Summative Intersection Point Height exhibited strong convergent validity with Trail Making Tests A and B (rho = 0.49, p < 0.001)”

    Humansn = 146

    Reliability and validity of the force intersection point in the assessment of human quiet standing balance

    Human movement science

More on Trail Making Test

Latest

Dec 2025: 0Jan 2026: 0Feb 2026: 0Mar 2026: 0Apr 2026: 0May 2026: 0Jun 2026: 0Jul 2026: 1Aug 2026: 0Sep 2026: 0Oct 2026: 0Nov 2026: 01 paper in 12 months