DXA T-score

There are 60 papers on DXA T-score in aging research: 2 trials and 55 observational studies in people, 1 review. The newest story, Nov 13, 2026: “AI shows promise for osteoporosis screening from X-rays”.

Biomarker

60 papers study it38 more mention it18 findings

8 new papers in 30 daysSee all 98 papers on DXA T-score

“A combination of baseline FN T-score, TH T-score, lumbar spine T-score, and spine fracture-like deformity assessment predicted 68.1% of the female cases with a follow-up hip FFx”
Majority of hip fragility fractures among older people can be predicted by a DXA examination: an updated analysis of literature results and empirical Chinese data with a focus on the validation of the newly proposed osteofrailia criterion for menQuantitative imaging in medicine and surgery2024doi:10.21037/qims-2024-2568
  • Human trial2
  • Humans55
  • In silico2

Upstream

1

FBQcsf

no changein humans1

1 study
  1. FBQcsf was not clearly linked with DXA T-score in humans (at-risk patients) (p = 0.151).

    Humansat-risk patientship or pelvisn = 248

More on FBQcsf

Associations

16

Hounsfield unit

upin humans2

2 studies
  1. Hounsfield unit is associated with DXA T-score in humans (r = 0.54, P < .001).

    Humanslumbar spinefemalesn = 229

  2. Hounsfield unit is associated with DXA T-score in humans (Spearman's ρ = 0.467, AUC = 0.700 (95% CI 0.614-0.781)).

    Humansn = 180

More on Hounsfield unit

Sagittal mean Hounsfield units

upin humans1

1 study
  1. Sagittal mean Hounsfield units are associated with DXA T-score in humans (Spearman ρ = 0.532, P < .001).

    HumansL1-L4 lumbar vertebrae120 females, 28 malessn = 148

More on Sagittal mean Hounsfield units

Vertebral bone quality

downin humans1

1 study
  1. Vertebral bone quality is associated with DXA T-score in humans (at-risk patients) (r = -0.307).

    Humansat-risk patientslumbar spinen = 248

More on Vertebral bone quality

Vertebral Hounsfield-unit CT attenuation

upin humans1

1 study
  1. Vertebral Hounsfield-unit CT attenuation is associated with DXA T-score in humans (R = 0.42).

    Humanslumbar vertebran = 91

More on Vertebral Hounsfield-unit CT attenuation

Volumetric Hounsfield unit

upin humans1

1 study
  1. Volumetric Hounsfield unit is associated with DXA T-score in humans (r = 0.572, p < 0.001).

    Humansbonen = 97

More on Volumetric Hounsfield unit

Calcium density

upin humans1

1 study
  1. Calcium density is associated with DXA T-score in humans (low-dose PCD CT) (r = 0.67, P < .001).

    Humanslow-dose PCD CTlumbar vertebran = 94

More on Calcium density

TLS-VBQ score

downin humans1

1 study
  1. TLS-VBQ score is associated with DXA T-score in humans (spinal surgery candidates) (r = -0.772 versus -0.708 for L1-4 VBQ).

    Humansspinal surgery candidatesvertebran = 218

More on TLS-VBQ score

CT-derived Hounsfield units

upin humans1

1 study
  1. CT-derived Hounsfield units are associated with DXA T-score in humans (liver transplant recipients).

    Humansliver transplant recipientslumbar spine and femoral neck62.9% malesn = 259

More on CT-derived Hounsfield units

Muscle fat infiltration

downin humans1

1 study
  1. Muscle fat infiltration is associated with DXA T-score in humans (patients treated for osteoporotic vertebral fractures) (r = -0.242, p = 0.037).

    Humanspatients treated for osteoporotic vertebral fractureslumbar spinen = 142

More on Muscle fat infiltration

Lumbar biconcavity

downin humans1

1 study
  1. DXA T-score is associated with lumbar biconcavity in humans.

    Humanslumbar vertebrafemalesn = 1,638

All 16

Latest

Dec 2025: 2Jan 2026: 6Feb 2026: 6Mar 2026: 3Apr 2026: 5May 2026: 2Jun 2026: 4Jul 2026: 5Aug 2026: 4Sep 2026: 3Oct 2026: 5Nov 2026: 651 papers in 12 months
European Radiology

AI shows promise for osteoporosis screening from X-rays

The model classified bone health with 80.1% accuracy in internal testing, while comparison models had lower observed accuracy.The model classified bone health with 80.1% accuracy in internal testing, while comparison models had lower observed accuracy.

Cross-sectional · 854 peopleOsteoporosis
Biomedical Optics Express

Machine learning reconstructs bone signals in human cadaver hands

Across 38 cadaver hands, reconstructed bone signals had an average correlation of 0.987 with signals measured after the bones were exposed.Across 38 cadaver hands, reconstructed bone signals had an average correlation of 0.987 with signals measured after the bones were exposed.

Cross-sectional study of 38 peopleBiomarkers

See all 98 papers on DXA T-score