Journal of Medical Systems · Oct 6, 2016

Estimation of Temporal Gait Events from a Single Accelerometer Through the Scale-Space Filtering Idea

By González I, Fontecha J, Hervás R et al.

The purpose of this paper is to develop an accelerometry system capable of performing gait event demarcation and calculation of temporal parameters using a single waist-mounted device. Particularly, a mobile phone positioned over the L2 vertebra is used to acquire trunk accelerations during walking. Signals from the acceleration magnitude and the vertical acceleration are smoothed through different filters. Cut-off points between filtered signals as a result of convolving with varying levels of Gaussian filters and other robust features against temporal variation and noise are used to identify peaks that correspond to gait events. Five pre-frail older adults and five young healthy adults were recruited in an experiment. Cadence, step/stride time, step/stride CV, step asymmetry and percentages of the stance/swing and single/double support phases, among the two groups of different mobility were quantified by the system.

doi.org/10.1007/s10916-016-0612-4PubMed 27714561Biomarkers