Journal of Physical Therapy Practice and Research · Nov 27, 2026
Is muscle strength assessment in older adults with dementia the same regardless of who measures it? Verification of interrater reliability between a practicing PT and a university faculty member
By 北風 草介, 中川 敬汰, 金井 秀作
INTRODUCTION: Today, in the midst of a super-aged society, physical therapy for older adults who have dementia (hereafter: older adults with dementia) is increasing. Muscle strength assessment in older adults with dementia tends to be avoided because of concerns about reproducibility. In our previous study, we reported that within-day and between-day intrarater reliability of knee extension strength assessment using a Hand-held dynamometer (hereafter: HDD) in older adults with dementia was high, with an ICC of 0.94 or higher. However, these results were obtained by the same examiner, and clinically, reliability must be ensured even when examiners differ. Therefore, this study examined interrater reliability between a practicing PT and a university faculty member with different years of experience and professional roles. OBJECTIVE: The purpose of this study was to examine whether manual muscle strength assessment in older adults with dementia could maintain reliability even with different examiners. METHODS: For muscle strength assessment, the dominant leg was the tested limb, and knee extension strength was measured using the H fixation method in a short sitting position. Measurements were performed by examiner A [a practicing PT with 17 years of experience] and examiner B [a university faculty member with 9 years of experience]. Each examiner performed 1 measurement per participant, for a total of 2 measurements, with measurements 1 and 2 performed on separate days. The assignment of examiners A and B to measurements 1 and 2 was randomized so that the measurement order of examiners A and B was balanced across participants. Measured values were converted to Nm/kg. For statistical analysis, the reliability of muscle strength assessment was assessed using the intraclass correlation coefficient ICC(2,1), and measurement error was evaluated using Bland-Altman analysis. Analyses in this study were performed using the statistical software R (version4.13), with the significance level set at 5%. RESULTS: Interrater reliability was moderate, with ICC(2,1) values of 0.62–0.68. Bland-Altman analysis revealed neither fixed nor proportional bias. No association was found between HDS-R scores and measurement error. Meanwhile, MDC95 was 0.66Nm/kg. DISCUSSION: These results suggested that manual muscle strength assessment in older adults with dementia has a certain degree of reproducibility even when examiners differ. However, considering factors such as the lack of involvement of cognitive function in measurement error, the lower reliability compared with assessment by the same examiner may have been influenced by differences in measurement techniques between examiners, such as the timing of verbal cues and how the direction of movement was communicated. We believe that testing older adults with dementia requires standardization of measurement methods tailored to dementia, including word choice suited to their comprehension and the timing needed to convey information. ETHICAL CONSIDERATIONS, EXPLANATION, AND CONSENT: This study was conducted after approval was obtained through research ethics review at the affiliated institution.
doi.org/10.14870/jptpr.36.supplement.46Powered by J-STAGEBiomarkers