The Journal of Korean Institute of Information Technology · Aug 31, 2026
Predicting 6-Minute Walk Distance from Short-Duration Exercise Tests using Wearable ECG and Accelerometer Signals in Elderly Cardiac Rehabilitation Patients
By Oh S
The 6-minute walk test (6MWT, 6-Minute Walk Test) is a standard test for assessing functional capacity in cardiac rehabilitation, but it requires sustained effort and sufficient walking space. This study compared whether wearable electrocardiogram (ECG) and accelerometer (ACC) signals measured during five exercise tests could predict 6MWT distance in 80 frail older patients (Edmonton Frail Scale ≥ 4) who underwent open-heart surgery. Signals were recorded using a single chest-worn device, and RidgeCV and Random Forest models were evaluated under leave-one-subject-out cross-validation (LOSO). ACC signals from stair climbing (ρ = 0.37) and TUG (ρ = 0.36) provided the strongest predictions, with stride cycle and cadence as the main predictors. Combining these signals with ECG did not provide a significant improvement, and signals from the cycling exercise test did not transfer to walking ability. Brief wearable measurements showed potential to complement the 6MWT.