AHA Scientific Sessions 2026 Abstract · Nov 2, 2026

Proportion of Home Blood Pressure Readings in Target Range During 12 Months of Remote Patient Monitoring

By Flanagan C, Smith W

Introduction: The 2025 AHA/ACC hypertension guideline reaffirmed a systolic blood pressure (SBP) target of <130 mmHg and encouraged pursuit of <120 mmHg when feasible. Control is typically judged from one or a few office readings that estimate central tendency. Remote patient monitoring (RPM) provides frequent automated home measurements, enabling assessment of the proportion of readings within target range, a blood pressure analog of “time in range.” Because BP variability predicts cardiovascular risk independent of mean BP, this metric may provide clinically relevant information beyond average SBP. Hypothesis: Among RPM patients, the proportion of home SBP readings within target range increases over 12 months in association with BP reduction, with larger gains among patients with higher baseline SBP. Furthermore, a controlled mean SBP understates residual variability that this metric reveals. Methods: Retrospective cohort study of adults active ≥12 months on RPM at eight U.S. cardiovascular practices, transmitting on ≥16 days during each of the first 12 months. Baseline SBP was defined as the mean SBP from the first two transmitting days; patients were stratified by baseline SBP (<120, 120-<130, 130-<140, 140-<150, and 150-<160 mmHg). For each patient-month, the percentage of readings below target (<130 and <120 mmHg) was calculated. Month 1 and month 12 were compared within strata using paired t-tests. Among patients with a month-12 mean SBP <130 mmHg, the distribution of the proportion of readings <130 mmHg was examined. Values are presented as mean ± SEM. Results: A total of 2,987 patients (mean age 77-79 across strata) qualified. Among 1,935 patients with a month-12 mean SBP <130 mmHg, only 55.3% had ≥80% of readings <130 mmHg, indicating that a controlled mean frequently masked substantial residual out-of-range readings. For the <130 mmHg target, the proportion of in-range readings increased from month 1 to month 12 in every elevated baseline stratum: 130-<140 mmHg, 46.0% to 58.7% (+12.7); 140-<150 mmHg, 27.8% to 46.5% (+18.7); and 150-<160 mmHg, 17.0% to 41.3% (+24.3) (all p<0.001). The <130 mmHg baseline group remained stable (74.3% to 72.5%). For the <120 mmHg target, significant improvements were observed across all elevated strata (+9.8 to +12.1 percentage points; all p<0.001). Mean SBP declined progressively with increasing baseline SBP (130-<140: -7.5 mmHg; 140-<150: -13.4 mmHg; 150-<160: -21.4 mmHg). Conclusions: Over 12 months of RPM, the proportion of home SBP readings within guideline target ranges increased progressively with higher baseline SBP. Importantly, a controlled mean SBP concealed substantial residual variability that was revealed by the proportion-of-readings metric. RPM enables quantification of BP readings-in-range, a measure that captures consistency of control and may provide clinically relevant information beyond mean SBP alone.

doi.org/10.1161/circ.154.suppl_1.17476Biomarkers

AgingResearch.News