AHA Scientific Sessions 2026 Abstract · Nov 2, 2026

Wearable-Derived Step Activity Associates with Echocardiographic Diastolic Function Measures and Reveals a Sex-Specific Interaction in the Project Baseline Health Study

By Ashar P, Jeong H, Nguyen D et al.

Introduction: Consumer wearable devices enable objective, continuous measurement of average daily physical activity at population scale. Whether step-derived activity metrics are independently associated with subclinical cardiac structure and function has not been systematically evaluated in large prospective cohorts. Hypothesis: Wearable-derived step metrics are independently associated with echocardiographic measures of cardiac structure and function. Methods: We included 2,333 participants (mean age 50.8±17.1 years; 55% female) from the Project Baseline Health Study (PBHS), a 4-site prospective U.S. cohort, wearing a Verily Study Watch. During the first 6 months post-enrollment, we examined cross-sectional associations between ten baseline echocardiographic variables and eight wearable step metrics: mean steps/day, standard deviation [SD], peak steps, 90th percentile of daily steps, coefficient of variation [CV; relative variability], proportion of days exceeding 7,500 steps, first 30-day step slope, and longitudinal step slope [full follow-up]. Linear regression adjusted for age and sex was applied to all step-echo pairs. Sex-by-step interactions were formally tested (α=0.05). Binary echo thresholds followed American Society of Echocardiography (ASE)/EACVI guidelines. Results: Higher step activity was associated with lower E/e' ratio (r=-0.230 to -0.283, all p<0.001; R ² =0.320) and higher E/A ratio among participants with normal to mildly impaired relaxation (r=+0.171 to +0.249, all p<0.001; R ² =0.359). Step standard deviation, capturing heterogeneity of daily activity patterns, was the strongest predictor (r=-0.283 for E/e', β=-0.219 per 1,000 steps/day adjusted). All diastolic associations persisted after age-and-sex adjustment. A significant sex-by-step interaction was identified for E/e' (p=0.011), with an approximately 2-fold stronger association in women (β=-0.133 per 1,000 average daily steps) than men (β=-0.062). In group comparisons, patients with elevated E/e' walked substantially less than those without (median 4.0k vs. 7.7k steps/day, p<0.001); those with lower E/A (<0.8) also had lower step counts (6.6k vs. 7.8k, p<0.001). Higher step activity was also associated with larger indexed LV volumes (higher LV volume group walked more: 8.4k vs. 7.2k, p<0.001). Conclusions: Higher average daily step activity, measured by consumer wearables, was independently associated with better diastolic measures in an adult cohort. The stronger association in women is a novel finding with implications for sex-specific physical activity monitoring in populations at elevated HFpEF risk. These findings support consumer wearables as a scalable, non-invasive tool for health monitoring, especially among women with low physical activity.

doi.org/10.1161/circ.154.suppl_1.16758Populations

AgingResearch.News